Moisture testing a basement slab before new floors

Before any floor goes on a basement slab, the concrete should be tested and the reading compared with the flooring maker’s written limit. The two tests makers name are the in-slab relative humidity test (ASTM F2170) and the calcium chloride test (ASTM F1869). A taped-down plastic sheet or a handheld meter is a useful first look, and that’s all it is.

By Keystone Flooring Co5 min read

Why test a slab that looks dry

Most basement floors look dry. The concrete is gray, dusty and cool to the touch. But concrete is porous, and a slab poured straight onto soil passes water vapor up from the ground below it all year long.

In many older homes there’s no plastic sheet under the slab at all. The Department of Energy’s Building America guidance for new slabs calls for 6-mil plastic sheeting or taped rigid foam over a gravel layer, which tells you what a lot of older basements are missing.

That vapor is harmless while it can escape into the room. Put a floor on top and it collects underneath. ASTM describes the results of too much moisture under a floor covering as debonding, peaking, breakdown of the finish flooring, and microbial growth. A test tells you whether that’s likely before you’ve paid for anything.

The in-slab humidity test (F2170)

ASTM F2170 measures relative humidity inside the concrete. Small holes are drilled partway into the slab, a sleeve and sensor are sealed into each hole, and the reading is taken once the sensor has settled, following the timing in the standard. The result is a percentage, such as 78% or 88%.

The advantage is that it reads the moisture deeper in the slab, which is closer to what the floor will live with once it’s covered and the surface can no longer dry to the room. ASTM notes the in-slab method is the better fit for thick slabs and slabs with no vapor retarder under them, and that describes plenty of basements in Western Pennsylvania and Northern West Virginia.

How many holes? Shaw’s SPC installation guidelines call for three relative humidity tests in areas up to 1,000 square feet, plus one more for each additional 1,000 square feet. Tests belong in the middle of the floor and near trouble spots, not just the driest corner.

The calcium chloride test (F1869)

ASTM F1869 is the older of the two methods. A patch of concrete is cleaned down to bare slab, a small dish of dry calcium chloride is weighed and set on it, and a plastic dome is sealed over the top. The salt pulls in the moisture coming off the concrete. When the test ends, the dish is weighed again.

The result is written in pounds of moisture over 1,000 square feet in 24 hours. A reading of 3 means three pounds of water vapor leaving each 1,000 square feet of slab per day. The standard excludes surfaces with coatings or sealers, so a painted basement floor has to be taken down to bare concrete where the dome sits.

Because it only measures what’s leaving the top of the slab at the time, the calcium chloride test is more affected by the room’s temperature and humidity than the in-slab test. Some makers accept either one, and some name only one.

Quick checks: plastic and meters

Two quick checks are common, and both have a place.

  • A plastic square taped to the floor. Tape a piece of clear plastic flat to the concrete on all four sides and leave it for a day or two. If the concrete underneath darkens or the underside fogs, moisture is coming up through the slab. If beads form on top, that’s humid room air condensing on a cool floor. It’s a rough home check, and none of the installation guides we work from set a limit for it.
  • A handheld meter. Electronic concrete meters read the surface layer in seconds. ASTM’s own standard for them, F2659, calls them a preliminary evaluation. They’re good for finding the wet part of a floor and deciding where a proper test should go.

Neither quick check replaces the plank maker’s test. ASTM’s electronic-meter guide says the meters read roughly the top inch of the slab, which is the part most affected by the room’s air.

If either quick check shows moisture, that’s useful. If both look dry, the slab still needs a real number before an expensive floor goes down.

Reading the numbers against the limit

A moisture reading means nothing until it’s compared with the limit printed in the installation guide for the product going down. Shaw’s guidelines for its SPC products allow up to 8 pounds by calcium chloride and 90% relative humidity by F2170, and ask for a concrete pH between 7 and 10. A glue-down floor also has to meet the adhesive’s own limit, which Shaw tells installers to check on the adhesive label.

Other planks and adhesives set lower numbers, so the same slab can pass for one product and fail for another. That’s the reason the plank is usually chosen before the final reading gets its verdict.

The Shaw guide adds two points worth knowing. A test shows conditions only at the time it was run. And while the installer may not be the one who runs the test, it’s the installer’s job to make sure the tests were done and the results are acceptable before the floor goes in.

When a slab reads high

A high reading rarely ends the project. It changes the plan.

  • Find the source. Downspouts, grading and gutters come first. DOE’s guidance on existing basement floors says sealing the slab won’t stop dampness if outside water is the cause.
  • Dry the room. Run a dehumidifier for a few weeks and test again. A slab that was reading the summer air can come down.
  • Add a barrier. A 6-mil poly sheet with taped seams, or a product rated for higher moisture, can fit a slab that’s close to the line.
  • Choose a different product. A floating SPC plank usually tolerates more slab moisture than a glue-down floor, because the adhesive has its own limit.

Retesting matters. A slab that failed in August and passes in November after a season of dehumidifying is a slab that can take a floor, as long as the dehumidifier keeps running in the humid months.

If there’s standing water after storms, or water pushing up through cracks, the basement needs a drainage fix first. Waterproof plank handles spills, leaks and a damp slab. Standing floodwater is a different matter.

Where testing fits in a job

At our free measurement, the installer takes a moisture reading on the slab and compares it with the limit for the plank you’re considering. If the reading is borderline, or the basement has a history of water, a full F2170 or F1869 test is the next step before anything is ordered. More on the rest of the job is on our basement floors page.

As an estimate, vinyl plank runs $5 to $12 per square foot installed, before your discount. A separate vapor barrier and slab patching are the moisture-related items that can push a basement toward the top of that range, and you’ll see them listed in writing before you decide.

Sources: ASTM F2170 (in-slab relative humidity) · ASTM F1869 (calcium chloride) · ASTM F2659 (electronic meters, preliminary evaluation) · Shaw installation guidelines for SPC products · DOE Building America: existing basement floors

Free measurement · step 1 of 6

Ready for a real number?

Tap one to start. Takes about a minute.

Questions

More answers

What is a good moisture reading for concrete before vinyl plank?

Whatever the plank maker’s guide allows. Shaw’s SPC guidelines accept up to 90% relative humidity by ASTM F2170 or 8 pounds by the ASTM F1869 calcium chloride test. Other products and adhesives set lower limits.

Which moisture test is better, F2170 or calcium chloride?

Both are accepted by many makers. The in-slab F2170 test reads deeper in the concrete and is less affected by the room’s air, and ASTM notes it suits slabs with no vapor retarder underneath. Use the one your plank maker names.

Can I test my basement slab myself?

You can do a quick check with a square of plastic taped to the floor. It shows whether moisture is coming up, but it doesn’t give the number a flooring maker’s limit is written in.

Does a dry-looking slab still need testing?

Yes. Concrete gives off vapor you can’t see, especially an older slab with no plastic sheet underneath. A floor on top traps that vapor.

What if the slab fails the moisture test?

Find the water source, dry the room with a dehumidifier and retest, or add a vapor barrier or a product rated for more moisture. If water stands on the floor after storms, the drainage has to be fixed first.

Will the moisture reading change with the seasons?

It can. A test shows the slab on the day it was taken. That’s one reason many basement installs add a vapor barrier even when the reading passes.

Free, no obligation

Get your free measurement


Answer five quick questions. We’ll call to set a time that works, measure the rooms, and give you a written number.

Licensed, insured prosBonded installers
Free in-home measurementAnd design consultation
Financing availableFor qualified applicants

Start here

Takes about a minute.

Step 1 of 6

What floor are you replacing?

Free in-home measurement. No obligation.